Read Data via WebSocket v2
Version 2 of the real-time API streams typed messages. You choose which message types to receive, and besides heart rate the connection can deliver the battery level of the user's heart rate monitor or watch and data ingestion pause notifications.
Request
URL
wss://dev.pulsoid.net/api/v2/data/real_time
Required scope
Depends on the requested types, see the table below
Authentication
Provide your OAuth2 Bearer token using one of the following methods:
Query parameter
wss://dev.pulsoid.net/api/v2/data/real_time?access_token=YOUR_TOKEN
Header
Authorization: Bearer YOUR_TOKEN
Query Parameters
access_token
string
OAuth2 access token (alternative to Authorization header)
types
string
heart_rate
Comma-separated list of message types to subscribe to
Available Message Types
heart_rate
data:heart_rate:read
Real-time heart rate updates
battery_level
data:battery_level:read
Battery level of the measuring device (heart rate monitor or watch)
ingestion_pause
data:heart_rate:read
Pulsoid paused accepting the user's data until a given time
To subscribe to multiple types, separate them with commas:
The token must have the scope of every requested type, otherwise the connection is rejected with HTTP 400 and error code 6003. Unknown types are ignored.
Connection Status Codes
101
Connection established
400
The token does not have the scope required by a requested type
401
Missing or invalid token
The server closes the connection when the token is revoked or expires.
Websocket URL Request Example
Response Messages
All messages are JSON objects with the following base structure:
type
string
The message type (see table above)
timestamp
string
ISO 8601 timestamp of when the value was taken
Each message includes a payload field matching its type: heartRate, batteryLevel or ingestionPause. In most cases a message carries a single value, but it may carry several values at a time, so read the fields you need and ignore the rest.
heart_rate
heartRate.bpm
integer
Heart rate in beats per minute
battery_level
The battery level of the device that measures the heart rate, that is the user's heart rate monitor or watch. It is not the battery of the phone or computer running the Pulsoid app.
batteryLevel.percent
integer
Battery level of the measuring device, from 0 to 100
ingestion_pause
Sent when Pulsoid pauses accepting the user's data. Until ends_at, no heart_rate or battery_level messages are delivered. There is no separate message when the pause ends, data simply starts flowing again.
If a pause is active when you connect, the message is sent right after the connection is established. If a new pause starts before the current one ends, you receive another ingestion_pause message and its ends_at applies.
ingestionPause.id
string
Unique identifier of the pause
ingestionPause.started_at
string
ISO 8601 timestamp of when the pause started
ingestionPause.ends_at
string
ISO 8601 timestamp of when the pause ends
JavaScript Example